DC electric motors
M61

Dc electric motors diameter 61 standard m61

M61

Stall torque from 2,95Nm to 1,05Nm

The M61 motors are electric motors equipped with filter.

The filter, which is normally made of an LC-circuit, allows the electric motors to be tested in compliance with the EMC directive.

In the technical datasheet it is possible to select the motor shaft and special cables which have to be indicated in the enquiry form.

In the table named “Electrical Data” it is indicate the voltage range of the M61 motors’ applications and a list of the performances for the most commonly used voltage values, 12V ad 24V.

The interactive curve allows to select the required performances by selecting power voltage and no-load speed.

Applications

The M61 electric motors are generally applied in linear actuators and in various automatisms.

Electric data

12 V 24 V
Standard nominal voltage 12 V 24 V
No load speed
N0 [Rpm]
7000÷2500 7000÷2500
No load current
I0 [A]
2.30÷0.80 2.30÷0.80
Nominal speed
Nn [Rpm]
6848÷2349 6848÷2349
Nominal torque
Mn [Nm]
0.06 0.06
Nominal current
In [A]
5.90÷2.10 2.95÷1.05
Nominal power
Pn [W]
45.90÷15.70 37.80÷12.20
Stall torque
Ms [Nm]
2.95÷1.05 2.95÷1.05
Starting current
Is [A]
171÷22 85.50÷11
Max power
Pmax [W]
542÷69 542÷69
Max efficiency
ηmax [%]
84÷69 84÷69

Mechanical data

Type of duty Depending on application
Weight 0.95

Technical drawing

Dc electric motors diameter 61 standard m61

Shaft

Select the shaft for your motor :

Filter



Set the characteristic curve

The characteristic curve of the DC electric motors is made of a diagram represented in the Cartesian axis based on the values which are inserted, where once can see represented the torque, in [Nm] (axis X); the rotation speed, in [Rpm] (axis y1); the absorbed current, in [A] (axis y2); the efficiency (axis y3).

No-load RPM motor:
Power voltage:







Ask for a quotation for this motor

Please note that we do not sell to private buyers and that we cannot supply any replacement motor.